A compact 12V and 24V 97×94×33mm DC blower fan delivering up to 52.27CFM airflow and 113.74mmH₂O static pressure for directed cooling in high-resistance airflow systems.

The DC9733 blower fan uses a centrifugal structure to draw air through the inlet and discharge it through a side outlet. Five speed levels from 2500 to 6500RPM allow engineers to balance airflow, static pressure, noise and current for different equipment cooling requirements. Available in 12V and 24V versions, DC9733 provides 19.56–52.27CFM airflow, 12.35–113.74mmH₂O static pressure and 41.65–63.60dBA noise levels. Optional PWM, FG, RD, Auto Restart and Polarity Protection functions support equipment control and operating-status monitoring.

Rated Voltage: 12VDC / 24VDC

Size: 97*94*33mm

Speed Range: 2500–6500RPM

Airflow Range:19.56–52.27CFM

Static Pressure Range:12.35–113.74mmH₂O

Noise Range: 41.65–63.60dBA

Weight: 175g

Request a Sample

Key Specifications of DC9733 Blower Fan

Compare the 12V and 24V DC9733 models by current, speed, airflow, static pressure and noise to select the appropriate 97×94×33mm DC blower fan for the equipment.

ModelBearing
Type
Rated
Voltage(VDC)
Current
(A)
Speed
(RPM)
Air Flow
(CFM)
Static Pressure
(mmH₂O)
Noise Level
(dBA)
Weight
(g)
YBU9733X12S or B123.40650052.27113.7463.60175
YBD9733X12S or B121.50500040.1463.3857.25175
YBH9733X12S or B120.60350027.5626.5550.35175
YBM9733X12S or B120.40300023.4817.7847.00175
YBL9733X12S or B120.30250019.5612.3541.65175
YBU9733X24S or B241.70650052.27113.7463.60175
YBD9733X24S or B240.70500040.1463.3857.25175
YBH9733X24S or B240.40350027.5626.5550.35175
YBM9733X24S or B240.30300023.4817.7847.00175
YBL9733X24S or B240.20250019.5612.3541.65175

DC9733 High Static Pressure Blower Fan Advantages

DC9733 combines a compact centrifugal housing, five performance levels and 12V/24V compatibility for cooling systems with different airflow resistance, noise and power requirements.

Up to 113.74mmH₂O Static Pressure

The 6500RPM models provide up to 113.74mmH₂O static pressure, helping the 9733 centrifugal blower fan move air through restricted vents, dense heat sinks, filters and short internal ducts.

Up to 52.27CFM Directed Airflow

The centrifugal housing draws air through the inlet and redirects it through the side outlet. Airflow up to 52.27CFM supports cooling systems that need air delivered toward a defined component or exhaust path.

Five Performance Levels with 12V and 24V Options

Speed options of 2500, 3000, 3500, 5000 and 6500RPM are available for both 12V and 24V systems, allowing engineers to balance airflow, pressure, noise and current without changing the installation size.

Control and Protection Options

PWM enables speed adjustment according to thermal demand. FG provides rotational speed feedback, while RD can indicate an abnormal or locked rotor. Auto Restart and Polarity Protection can also be configured according to project requirements.

YCCFAN 97×94×33mm DC Blower Fan Product Overview

DC9733 97x94x33mm centrifugal blower fan dimension drawing

DC9733 is a 97×94×33mm DC blower fan designed for equipment that requires side-directed airflow. Its centrifugal structure guides air toward heat sinks, power components, filters, vents or short internal ducts.

The series offers 12V and 24V models with five speed levels from 2500 to 6500RPM. Airflow reaches up to 52.27CFM, while static pressure reaches up to 113.74mmH₂O. Bearing, wiring, connector and control functions can be selected according to equipment requirements.

DC9733 Blower Fan Airflow and Static Pressure Curve

Use the DC9733 P-Q curve to compare airflow and static pressure across different 12V and 24V models and select the appropriate performance level for the system resistance.

DC9733 blower fan airflow and static pressure performance curve

Applications of the DC9733 97mm Blower Fan

With side-directed airflow, five output levels and up to 113.74mmH₂O static pressure, DC9733 is suitable for compact equipment with defined airflow paths, dense components or higher internal resistance.

Get Cooling Support
DC9733 blower fan used for server and network equipment cooling applications

Server and Network Equipment

The DC9733 blower fan can support compact server modules, network appliances, communication terminals and equipment cabinets where processors, power components and heat sinks are arranged within limited space. Its side outlet guides airflow through a defined cooling path.

DC9733 blower fan cooling industrial control cabinets and power distribution enclosures

Power Distribution and Control Enclosures

Industrial controllers, power converters, motor drives and power distribution enclosures often contain concentrated heat sources and limited exhaust space. The high static pressure DC9733 blower can direct cooling air toward power components or through an internal air channel.

97mm DC9733 blower fan installed in printer and imaging equipment cooling systems

Office and Imaging Equipment

The 97×94×33mm DC blower fan can be used in printers, copiers, scanners and imaging equipment containing motors, power supplies, heating components or enclosed control boards. Lower-speed models support tighter acoustic requirements.

DC9733 blower fan used in compact air handling and filtration equipment

Air Handling and Filtration Equipment

DC9733 can support compact ventilation units, filtration modules and air treatment equipment where air needs to pass through a filter, internal channel or restricted discharge path. Model selection should consider the P-Q curve and actual system pressure loss.

97mm centrifugal DC9733 blower fan cooling battery testing and charging equipment

Battery Testing and Charging Equipment

Battery test and charging equipment contains heat-generating power modules and heat sinks. The 97mm centrifugal blower fan directs cooling air through dense layouts and restricted exhaust openings.

DC9733 97×94×33mm Blower Fan Video Showcase

Watch DC9733 in operation to examine its centrifugal housing, inlet, side outlet, mounting structure, airflow direction and optional control functions.

The DC9733 video provides a visual reference of the centrifugal housing, inlet, side outlet and mounting structure, helping engineers review the product profile before integration into their equipment.

It allows users to examine the airflow direction and key mechanical details to confirm whether the fan matches the installation requirements.

The video also shows optional control functions of DC9733 for equipment design and application evaluation.

FAQs About DC9733 Blower Fan

When should engineers choose DC9733 instead of an axial fan?

A: Choose DC9733 when air must enter through the inlet and leave through a side outlet, especially when airflow needs to be guided toward a heat sink, filter, restricted vent or short internal duct. An axial fan is generally more suitable for direct airflow through an open, low-resistance enclosure.

Which DC9733 speed model should be selected?

A: Select the speed level according to the airflow and static pressure required at the equipment’s actual operating point. The 6500RPM model provides the highest output, while the 2500RPM model has the lowest listed current and noise. A higher-speed model is not automatically the best option because excess output can increase noise and power consumption.

How should the actual operating point of DC9733 be determined?

A: The actual operating point is where the selected DC9733 P-Q curve intersects the equipment’s system resistance curve. Filters, heat sinks, narrow vents, grilles and ducts increase resistance and reduce airflow. Maximum airflow and maximum static pressure should not be treated as values achieved simultaneously.

How do inlet clearance and outlet design affect DC9733 performance?

A: Insufficient inlet clearance restricts air entry. An undersized duct, sharp outlet bend or obstructed exhaust opening increases turbulence and pressure loss. Leave adequate space around the inlet, align the outlet with the intended airflow path and avoid placing cables directly in front of either opening.

What information should be provided when requesting a DC9733 model?

A: Provide the rated voltage, required airflow, estimated system resistance, maximum acceptable noise, installation orientation, inlet clearance, operating temperature, duty cycle and required control signals. Wire length, connector type, bearing preference, target quantity and project stage should also be included.

How should a customized DC9733 sample be validated?

A: Install the sample in the actual equipment or a representative airflow fixture. Test component temperatures, fan speed, input current, noise, vibration and startup behavior. If PWM, FG or RD is used, also verify speed-control response, feedback signals and locked-rotor alarm logic.

Can't Find the Perfect Fan?

We offer customization services from wire length to full mold design. Get a solution in 48 hours.

Request Custom Solution